microscope light source

microscope light source
  • microscope light source
  • microscope light source
  • Ocular Micrometer
  • Stage Micrometer
  • Compatible size
  • micrometer calibration
  • traceability certification
  • specimen
  • inquiry form
  • order form


  Compatible Size List for Eyepieces and Ocular Micrometers


The required ocular micrometer size varies by microscope manufacturer and
eyepiece model (part number). Please check the table below before placing your order.

   Nikon Eyepiece Models 
In addition to magnification, eyepieces may be labeled with "CFW 10x/22," etc.
The "/22" indicates the field of view, not the micrometer's diameter.

Eyepiece Model
Micrometer
Size/mm
Possible Microscope Model
 C-W 10x B/22 (C-W 10x A/22) Φ 25  SMZ-1500
 SMZ-1000 / SMZ-800
 SMZ-745
 SMZ-645 / SMZ-660
 SMZ-1
 C-W 15x /16 Φ 19
 C-W 20x Φ 19
 CFI 10x CFI 12.5x CFI 15x Φ 27  
 CFI UW 10x Φ 27  
 CFUW10x N/A  
 CFW 10x CFW 15x Φ 21  
 CFWN 8x | 10x |15x Φ 21  
 CFUWN 10x N/A  
 CFUWN 15x N/A  
 E1-CFI 10x| E2-CFI 10x | E2-CFI 15x Φ 27  Eclipse E100 / E200
 SME 10x /23 N/A  SMZ
 SM-5
 SM-6
 SME 15x N/A  SMZ-1
 SME 20x N/A
 SME 20x /12 N/A
 SME 10x /21 N/A  SMZ-1
 SME 33x /5 Φ 10
 SMZ U UW10x A/24 Φ 25  SMZ-U
 SMZ U UW15x Φ 25
 SMZ U UW20x Φ 21
 SMZ U UW30x N/A
 SMZ 10 E10xA φ 24  SMZ-10
 SMZ 10 UW15x /17 φ 27
 SMZ 10 UW20x N/A
 SMZ 10 UW20x 15 Φ 27  
 CFPL 2x Φ 19  
 CFPL 2.5x Φ 19  
 CFPL 4x Φ 19  
 CFPL 5x Φ 19  
 CFW 8x Φ 21  Optiphot / Optiphot 2 / TMD300 / TMD200
 CFWE10x / CFWE15x Φ 21  
 TS2-W10x Φ 25  TS2
 YS-CF10x / YS-CF15x Φ 21  YS2 / YS / SE2 SE / TMSE
 EL10x / EL15x Φ 21  EL (*Internal diopter correction is not available)
 HKW10x Φ 21  S / S-KE / L-KE


   Olympus Eyepiece models
In addition to magnification, eyepieces may be labeled with "CFW 10x/22," etc.
The "/22" indicates the field of view, not the micrometer's diameter.

 Eyepiece Model
Micrometer
Size/mm
Microscope Model
*combination is not limited to below list
 WHN10X | WHN10X -H Φ 24  BX61 / BX51 / BX41/ AX series 
 SWH10-H N/A
 WHB10X / WHB10X -H Φ 20.4  CX41 / CX43 / CX31P / CKX41
 WHC15X / WHC15X -H Φ 19
 WH10X | WH10X -H | WH15X Φ 24 (*)  BX50 / BX40
 WHS10X-H | WHS15X-H  SZX7 / SZX9 / SZX12
 WHS1Z10X  SZ61 / SZX7 / SZX10 / SZX16 
 WHS1Z10X-H
 WHS1Z15X-H
 WHS1Z20X
 WHS1Z20X-H / WHS1Z30X-H
 CWH10X | CWH10X-H | CWH30X  CX41
 GSWH10X | GSWH10X-H
 GSWH15X | GSWH15X-H
 GSWH20X | GSWH20X-H
 GSWH30X | GSWH30X-H
 GW10X
 SZ60 / SZ40 / SZ11 / SD / SF
 WH12.5X | WH12.5X -H
 GWH10X / GWH10X-D | GWH10X-CD Φ 26  SZH / SZH10
 SWHK 8X Φ 28  Vanox and other
 SWHK 10X N/A
 G10X | G15X Φ 22
 WHK8X | * WHK10X
 WHK15X | NWHK10X
 (* WHK10X-H is N/A)
 NFK 2.5X | 3.3X | 5X | 6.7X
 PE 2.5X | 3.3X | 4X | 5X
 GWH15X-D | GWH15X-CD
Φ 20.4
 Can be substituted with Φ20mm with slight
 looseness. Please contact us for details.

 To secure the micrometer to the WHK10X,
 the Olympus AF553000 fixing ring is required
.
 G20X-H Φ 20
 CWHK10X | NCWHK10X | G20X Φ 19  CK40 / CK30 / CH40 / CH30 / CH2
 NFK 2.5X | NFK 5X | NFK 20X
 NFK 3.3X | NFK 6.7X
(*) Olympus micrometers with φ24mm have a thickness of 1.5mm, while ours are 1.0mm.
  However, since the printed surface faces the objective lens,
  the optical distance remains the same, ensuring no issues in use.


   Carl Zeiss / Leica Eyepiece models
Carl Zeiss and Leica have not disclosed information on compatible micrometer sizes for their
eyepiece models or any required installation parts. Additionally, this information is restricted
to direct user inquiries. Please contact the manufacturer directly for further details.
Carl Zeiss Miroscope - Customer support (North America)
TEL : +1 800 327 9735
Mail : [email protected]
Leica Microscope - Customer support (US)
TEL : +1 800 248 0223